READ ALL THE INSTRUCTIONS
TOOLS & MATERIALS REQUIRED
QUESTIONS? CALL TOLL
FREE 1-800-345-0542
INSTALLATION & OPERATION INSTRUCTIONS
3” (7,6 mm) IC RECESSED LIGHTING KIT
ALL RIGHTS RESERVED. COPYRIGHT COMMERCIAL ELECTRIC 2011
MODELS: ???
Fig. 1
UNPACK THE FIXTURE
Check the contents of the box. You should receive:
1 Housing (can,
junction box)
1 - Trim assembly
1 Template
3 Remodel clips (pre-
attached to housing)
3 Wire Nuts
Insulation
WARNING: First disconnect electricity at the circuit breaker or the fuse
box. Disconnecting power by using the wall switch is not sufficient to
prevent electrical shock.
Choose the location for the fixture(s), keeping in mind the 6(15,2 cm) depth
clearance, accessibility for the electrical supply, and the ½” (1,3 cm)
clearance from the joists, floor boards, or any other combustible material.
REMODEL INSTALLATION
MAKING THE HOLE/RUNNING THE SUPPLY WIRING TO THE HOLE
1. Cut a 3 1/4 (8,3 cm) hole into the ceiling after choosing the appropriate
location. A template is provided to assist in making the hole. (Fig. 2)
2. Clear out any insulation necessary to maintain the 3 (7,6 cm) spacing
specified in the CAUTION section found in the beginning of these
instructions. (See Fig. 1)
3. Run armored cable (BX) or non-metallic (NM) cable (also known as
Romex) from your circuit breaker or fuse panel to the 3 1/4(8,3 cm) hole,
providing 6 (15,2 cm) to 8 (20,3 cm) of slack extending below the hole.
Cable having up to 12 AWG wiring may be used. (Fig. 3) (WARNING -
Use cables having wires rated 90°C or more.)
Hole
Ceiling
Cable
Hole
Fig. 2
Fig. 3
Keyhole saw
CAUTION
Before assembling your lighting fixture, refer to the ELECTRICAL
CONNECTIONS section. If you feel you do not have electrical wiring
experience, refer to a do-it-yourself wiring handbook or have your fixture
installed by a qualified licensed electrician.
NOTE: This fixture is an IC type fixture. It may come in direct contact
with thermal insulation. It can be completely covered by thermal
insulation, as shown below. In addition, any part of the fixture may
come in direct contact with any combustible material, such as a ceiling
joist or floor board. (FIG. 1)
BEFORE YOU BEGIN
1. To ensure the success of the installation, be sure to read these
instructions and review the diagrams thoroughly before beginning.
2. All electrical connections must be in accordance with local code and
ordinances. If you are unfamiliar with methods of installing electrical
wiring, secure the services of a qualified licensed electrician.
3. Before starting the installation, disconnect electricity at the circuit breaker
or the fuse box. Disconnecting power by using the wall switch is not
sufficient to prevent electrical shock.
4. Check if the power source is suitable for the added electrical load. Power
should be supplied by a 110/120 volt, 60 Hz single circuit. A standard 120
volt, 15 amp branch circuit is designed to carry a maximum load of 1800
watts. We recommend that the total wattage of all the lights and
appliances on that circuit, not exceed 80% or 1440 watts, of the maximum
electrical capacity.
5. This fixture is designed to be used on ceiling surfaces that are 3/8
(1,0 cm), 1/2 (1,3 cm), or 5/8 (1,6 cm) thick. It cannot be used on
any other ceiling thickness.
Out of the box, this product can be use in REMODEL applications. In a
remodel application, a ceiling surface already exists and there is no access
above the surface to the ceiling joists. To install this fixture, a hole must be
made in the existing ceiling from the room side. Then, electrical wiring must
be run to this hole and connected to the fixture. The fixture is, finally,
inserted into the ceiling hole, which secures itself to the ceiling surface,
using special remodel clips (provided). To use this product in NEW-
CONSTRUCTION applications, a Commercial Electric plaster frame and
Commercial Electric hanger bars must be purchased, separately. In a
new construction application, the ceiling surface has not yet been installed
and the ceiling joists are still exposed and accessible.
IMPORTANT NOTE
Ladder
BX or NM Cable
BX or NM Cable
Connectors
Keyhole Saw or 3 ¼”
(8,3 mm) Hole Saw
Flathead Screwdriver
Insulated Pliers
Pencil
UL Listed
Electrical Tape
4. Proceed to the “ELECTRICAL CONNECTIONS” section.
1. Slide the housing through the hole opening. (Fig. 4)
MOUNTING THE HOUSING TO THE CEILING
Fig. 4
Hole
Housing
Ceiling
GETTING STARTED
Remodel
clip
Seitenansicht 0
1 2 3 4 5 6 7 8 9

Inhaltsverzeichnis

Seite 1 - READ ALL THE INSTRUCTIONS

READ ALL THE INSTRUCTIONSTOOLS & MATERIALS REQUIREDQUESTIONS? CALL TOLL FREE 1-800-345-0542INSTALLATION & OPERATION INSTRUCTIONS –3” (7,6 mm

Seite 2 - NEW CONSTRUCTION INSTALLATION

Fig. 11Fig. 101. Raise the plaster frame and hanger bar assembly to the desired locationbetween the two ceiling joists. Adjust the width of both hange

Seite 3 - DROP CEILING INSTALLATION

1. Insert the light bulb into the socket and twist clockwise to lock it in place.2. Secure the bulb to the trim assembly by angling it into its mounti

Seite 4 - LEER TODAS LAS INSTRUCCIONES

LEER TODAS LAS INSTRUCCIONESHERRAMIENTAS Y MATERIALES NECESARIOS¿PREGUNTAS? LLAMA GRATIS AL 1-800-345-0542INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIEN

Seite 5 - Barra "Hembra"

Fig. 6TODOS LOS DERECHOS RESERVADOS. COPYRIGHT  COMMERCIAL ELECTRIC 2011Otro extremoAgujeroClip de remodelaciónCubierta2. Cuando la cubierta esté cas

Seite 6 - INSTALACIÓN EN TECHO FALSO

Fig. 15 Fig. 161. Inserte el foco en el portafocos y gire en dirección a las manecillas del reloj paraasegurarlo en su lugar.2. Asegure el foco en el

Seite 7 - LISEZ TOUTES LES INSTRUCTIONS

LISEZ TOUTES LES INSTRUCTIONSOUTILS ET MATÉRIAUX NÉCESSAIRESDES QUESTIONS? APPELEZ SANS FRAIS AU 1-800-345-0542MODE D’INSTALLATION ET D’EMPLOI POUR L

Seite 8

1rerainure –pliez ici1reencoche –pliez iciSection « mâle »rSection « femelle »TOUS DROITS RÉSERVÉS  COMMERCIAL ELECTRIC 2011Fig. 5FixationPiedBoîtier

Seite 9 - DÉPANNAGE

Barre en TCarreau pour plafondOrificeCadre à scellerBarres de suspensionSupport de barres de suspensionFig. 121. Insérez l’ampoule dans la douille et