READ ALL THE INSTRUCTIONS
TOOLS & MATERIALS REQUIRED
QUESTIONS? CALL TOLL FREE
1-800-345-0542
INSTALLATION & OPERATION INSTRUCTIONS
3” (7,6 mm) IC RECESSED LIGHTING KIT
ALL RIGHTS RESERVED. COPYRIGHT COMMERCIAL ELECTRIC 2013
MODELS: CER3LICR3730
UNPACK THE FIXTURE
Check the contents of the box. You should receive:
1 Housing (can, junction
box)
1 - Trim assembly
1 Template
3 Remodel clips (pre-
attached to housing)
3 Wire Nuts
WARNING: First disconnect electricity at the circuit breaker or the fuse box.
Disconnecting power by using the wall switch is not sufficient to prevent
electrical shock.
Choose the location for the fixture(s), keeping in mind the 6(15,2 cm) depth clearance,
accessibility for the electrical supply, and the ½” (1,3 cm) clearance from the joists, floor
boards, or any other combustible material.
REMODEL INSTALLATION
MAKING THE HOLE/RUNNING THE SUPPLY WIRING TO THE HOLE
1. Cut a 3 1/4 (8,3 cm) hole into the ceiling after choosing the appropriate location. A
template is provided to assist in making the hole. (Fig. 2)
2. Clear out any insulation necessary to maintain the 3 (7,6 cm) spacing specified in
the CAUTION section found in the beginning of these instructions. (See Fig. 1)
3. Run armored cable (BX) or non-metallic (NM) cable (also known as Romex) from
your circuit breaker or fuse panel to the 3 1/4 (8,3 cm) hole, providing 6 (15,2 cm)
to 8 (20,3 cm) of slack extending below the hole. Cable having up to 12 AWG wiring
may be used. (Fig. 3) (WARNING - Use cables having wires rated 90°C or more.)
Hole
Ceiling
Cable
Hole
Fig. 2
Fig. 3
Keyhole saw
BEFORE YOU BEGIN
1. To ensure the success of the installation, be sure to read these instructions and
review the diagrams thoroughly before beginning.
2. All electrical connections must be in accordance with local code and ordinances. If
you are unfamiliar with methods of installing electrical wiring, secure the services of a
qualified licensed electrician.
3. Before starting the installation, disconnect electricity at the circuit breaker or the fuse
box. Disconnecting power by using the wall switch is not sufficient to prevent
electrical shock.
4. Check if the power source is suitable for the added electrical load. Power should be
supplied by a 110/120 volt, 60 Hz single circuit. A standard 120 volt, 15 amp branch
circuit is designed to carry a maximum load of 1800 watts. We recommend that the
total wattage of all the lights and appliances on that circuit, not exceed 80% or 1440
watts, of the maximum electrical capacity.
5. This fixture is designed to be used on ceiling surfaces that are 3/8 (1,0 cm),
1/2 (1,3 cm), or 5/8 (1,6 cm) thick. It cannot be used on any other ceiling
thickness.
Out of the box, this product can be use in REMODEL applications. In a remodel
application, a ceiling surface already exists and there is no access above the surface to
the ceiling joists. To install this fixture, a hole must be made in the existing ceiling from
the room side. Then, electrical wiring must be run to this hole and connected to the
fixture. The fixture is, finally, inserted into the ceiling hole, which secures itself to the
ceiling surface, using special remodel clips (provided). To use this product in NEW-
CONSTRUCTION applications, a Commercial Electric plaster frame and
Commercial Electric hanger bars must be purchased, separately. In a new
construction application, the ceiling surface has not yet been installed and the ceiling
joists are still exposed and accessible.
IMPORTANT NOTE
Ladder
BX or NM Cable
BX or NM Cable
Connectors
Keyhole Saw or 3 ¼” (8,3
mm) Hole Saw
Flathead Screwdriver
Insulated Pliers
Pencil
UL Listed Electrical
Tape
4. Proceed to the ELECTRICAL CONNECTIONSsection.
1. Slide the housing through the hole opening. (Fig. 4)
MOUNTING THE HOUSING TO THE CEILING
GETTING STARTED
Fig. 4
Hole
Housing
Ceiling
Remodel
clip
Fig. 1
Insulation
CAUTION
Before assembling your lighting fixture, refer to the ELECTRICAL CONNECTIONS
section. If you feel you do not have electrical wiring experience, refer to a do-it-yourself
wiring handbook or have your fixture installed by a qualified licensed electrician.
NOTE: This fixture is an IC type fixture. It may come in direct contact with
thermal insulation. It can be completely covered by thermal insulation, as shown
below. In addition, any part of the fixture may come in direct contact with any
combustible material, such as a ceiling joist or floor board. (FIG. 1)
REV 03-DEC-2013
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - READ ALL THE INSTRUCTIONS

READ ALL THE INSTRUCTIONSTOOLS & MATERIALS REQUIREDQUESTIONS? CALL TOLL FREE 1-800-345-0542INSTALLATION & OPERATION INSTRUCTIONS –3” (7,6 mm

Seite 2 - NEW CONSTRUCTION INSTALLATION

1rerainure –pliez ici1reencoche –pliez iciSection « mâle »rSection « femelle »TOUS DROITS RÉSERVÉS  COMMERCIAL ELECTRIC 2013Fig. 5FixationPiedBoîtier

Seite 3 - DROP CEILING INSTALLATION

L'interrupteur ou le disjoncteur est fermé.Ouvrez l'interrupteur ou le disjoncteur.Les connexions électriques sont incorrectes ou lâches.Vér

Seite 4 - MODEL: RHPS311AL-JW1

TOUS DROITS RÉSERVÉS  COMMERCIAL ELECTRIC 2013GRADATION DE L’INTENSITÉ LUMINEUSEBien que ce produit convienne à la plupart des gradateurs résidentiel

Seite 5 - LEER TODAS LAS INSTRUCCIONES

1. Raise the plaster frame and hanger bar assembly to the desired location betweenthe two ceiling joists. Adjust the width of both hanger bars to the

Seite 6 - Barra "Hembra"

1. Plug the FEMALE CONNECTOR of the TRIM onto the MALE CONNECTOR of theHOUSING.2. Tuck all wires into the CAN and carefully push the TRIM into CAN.3.

Seite 7 - INSTALACIÓN EN TECHO FALSO

ALL RIGHTS RESERVED. COPYRIGHT  COMMERCIAL ELECTRIC 2013DIMMINGAlthough this product is compatible with most common residential type dimmers,dimming

Seite 8 - MODELO: RHPS311AL-JW1

LEER TODAS LAS INSTRUCCIONESHERRAMIENTAS Y MATERIALES NECESARIOS¿PREGUNTAS? LLAMA GRATIS AL 1-800-345-0542INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIEN

Seite 9 - LISEZ TOUTES LES INSTRUCTIONS

Fig. 6TODOS LOS DERECHOS RESERVADOS. COPYRIGHT  COMMERCIAL ELECTRIC 2013Otro extremoClip de remodelaciónCubierta2. Cuando la cubierta esté casi compl

Seite 10

1. Enchufe el CONECTOR HEMBRA del ADORNO DECORATIVO en el CONECTORMACHO de la CAJA.2. Coloque todos los cables en el Coloque todos los cables en el AL

Seite 11

TODOS LOS DERECHOS RESERVADOS. COPYRIGHT  COMMERCIAL ELECTRIC 2013Commercial Electricgarantiza este producto contra defectos en sus materiales ymano

Seite 12 - MODÈLE: RHPS311AL-JW1

LISEZ TOUTES LES INSTRUCTIONSOUTILS ET MATÉRIAUX NÉCESSAIRESDES QUESTIONS? APPELEZ SANS FRAIS AU 1-800-345-0542MODE D’INSTALLATION ET D’EMPLOI POUR L