1. Insert the light bulb into the socket and twist clockwise to lock it in place.
2. Secure the bulb to the trim assembly by angling it into its mounting clip.
3. Slide the trim assembly into the housing until it snaps into the place.
4. Installation is complete. Restore electrical power.
LIGHT BULB AND TRIM INSTALLATION (Fig. 15 & 16)
Fig. 15
Fig. 16
TROUBLESHOOTING
Wall sw itch or circuit breaker is
off.
Turn on sw itch or circuit breaker.
Incorrect or loose w ire
connections
Check wire connections
Light bulb may be dead. Test light
bulb in a know n w orking light
fixture.
Replace light bulb.
Light bulb is loose. Tighten light bulb in socket.
The light is turning off
after being on for
some time. Soon after,
it turns back on. The
light continues this
cycle indefinitely.
The thermal sensor turning off
due to excessive heat.
Space aw ay any insulation at
least 3" (7,6 cm) from the
housing, as show n in Fig. 1.
The light does not turn
on.
SYMPTOM POSSIBLE CAUSE SOLUTION
BX
Cable
Junction
box
door
Wire
nut
Housing
Metal tab
BX Cable
connector
Fig. 13
Fig. 14
Knockout
Housing
NOTE: In additional to the main supply cable entering the junction box, one
more cable may be fed into the junction box to provide electrical power to
another light fixture intended to be on the same circuit. No more than two
cables can be fed into the junction box. It is very important that the knockout
used for the second cable be adjacent to the knockout used for the first
cable. Avoid using a knockout that is on the opposite side of the first
knockout. Using an opposite knockout may make insertion through the
ceiling hole more difficult.
1. Open the junction box’s door by pulling on its metal tab.
2. Break off one of the round knockouts from the junction box using a
screwdriver. Secure an appropriately sized BX or NM (Romex) cable
connector to the knockout opening. Feed the BX or NM (Romex) cable
through the connector, providing 3 (7,6 cm) of slack inside the junction
box. Tighten the connector to secure the cable in place.
3. Remove at least 3 (7,6 cm) of the cable’s outer sheath and remove the
plastic or paper over-wrap. Strip approximately 3/8 (1,0 cm) of insulation
from the ends of all supply wires. Using wire nuts, make the following wire
connections:
WHITE SUPPLY WIRE (NEUTRAL) TO WHITE FIXTURE WIRE
BLACK SUPPLY WIRE (HOT) TO BLACK FIXTURE WIRE
GREEN/BARE SUPPLY WIRE (GRND) TO GREEN FIXTURE WIRE
ELECTRICAL CONNECTIONS (Fig. 13 & 14)
Be sure that there are no loose strands or loose wires.
4. Wrap all wire connections with electrical tape for a more secure
connection. NOTE: If you have electrical questions, consult your
local electrical code for approved grounding methods.
5. Carefully stuff all wires and wire connections into the junction box. Close
the junction box’s door.
ALL RIGHTS RESERVED. COPYRIGHT COMMERCIAL ELECTRIC 2011 . 2455 PACES FERRY RD. NW, ATLANTA, GA 30339
DROP CEILING INSTALLATION
1. Install a ceiling tile onto the T-bar grid at the installation location. Using the
provided template and a keyhole saw make a hole at the desired location in
the ceiling tile.
2. Place the plaster frame/hanger bar assembly onto the ceiling tile into the
newly created hole, making sure the bottom of the plaster frame feeds
through the hole. Adjust the width of both hanger bars to the distance
between the two T-bars, aligning each mounting clip with the top of its
corresponding T-bar. Press down on all mounting clips until they snap onto
the T-bar. NOTE: Holes are provided on the mounting clips that can be
used to secure the hanger bars to the T-bar. Parts (I.e. screws, hex nuts)
can be purchased separately for this purpose.
NOTE: Drop ceiling installations are similar to new construction
installations, except the hanger bars are attached to the T-bars of a drop
ceiling grid, instead of ceiling joists, as described below.
T-BAR INSTALLATION (Fig. 12)
T-bar
Ceiling
tile
Hole
Plaster
frame
Hanger
bar
Mounting
clip
Fig. 12
3. Proceed to Step 3 of the CEILING JOIST INSTALLATION section.
Light
bulb
Trim
Socket
Housing